Raw Wire
| All
raw wire is priced by the foot. |
Battery
Cable
Single conductor wire for higher amperage applications. Use this for
battery to battery jumpers, inverter inputs and main feeds between
batteries and load centers or disconnects. 100% copper wire. The insulation
is resistant to gas, oil, water and grease. |
| |
Wire,
Battery Cable, #6, Black |
$0.80 |
| |
Wire,
Battery Cable, #6, Red |
$0.80 |
| |
Wire,
Battery Cable, #4, Black |
$0.98 |
| |
Wire,
Battery Cable, #4, Red |
$0.98 |
| |
Wire,
Battery Cable, #2, Black |
$1.37 |
| |
Wire,
Battery Cable, #2, Red |
$1.37 |
| |
Wire,
Battery Cable, #2/0, Black |
$3.00 |
| |
Wire,
Battery Cable, #2/0, Red |
$3.00 |
| |
Wire,
Battery Cable, #4/0, Black |
$4.50 |
| |
Wire,
Battery Cable, #4/0, Red |
$4.50 |
|
UL
Listed Flexible Battery Cable
This is the cable we use to make battery interconnects. It is very
finely stranded and flexible. UL Listed. |
| |
Wire,
Battery Cable, UL, X-Flex, 2/0, Black |
$3.52 |
| |
Wire,
Battery Cable, UL, X-Flex, #2/0, Red |
$3.52 |
| |
Wire,
Battery Cable, UL, X-Flex, 4/0, Red |
$4.75 |
| |
Wire,
Battery Cable, UL, X-Flex, 4/0, Black |
$4.75 |
|
USE-2
Type Wire
Direct Burial/Sunlight Resistant - use this single conductor copper
wire for lead-in from PV arrays, wind and hydroelectric systems. It
may be used for AC or DC wiring up to 600 volts. Insulation is black
crosslinked polyethylene. 1/0 gauge and larger USE wire will be ordered
to the length you need, please allow 7 extra days for delivery. UL
listed. |
| |
Wire,
USE-2, #12 |
$0.20 |
| |
Wire,
USE-2, #10 |
$0.35 |
| |
Wire,
USE-2, #8 |
$0.42 |
| |
Wire,
USE-2, #6 |
$0.55 |
| |
Wire,
USE-2, #4 |
$0.80 |
| |
Wire,
USE-2, #2 |
$1.25 |
| |
Wire,
USE-2, #1/0 |
$1.74 |
| |
Wire,
USE-2, #2/0 |
$2.48 |
| |
Wire,
USE-2, #4/0 |
$3.42 |
|
TC
Type Cable
This 2 conductor flexible wire is excellent for outdoor applications
like PV array lead-in and sub array wiring. It may be buried directly
in the ground or exposed to direct sunlight. 10 and 12 gauge are good
for array interconnects. UL listed. |
Duplex
Primary Cable
This cable has two flexible stranded conductors covered with a vinyl
jacket. It is commonly used for low voltage house wiring. Since it
is stranded, it can be used in boats and RVs where vibration is encountered. |
Boat
Cable
This two conductor stranded wire looks like the duplex primary wire
above, but the wires are tinned copper and the insulation is UL approved
for marine use. |
4
Conductor Meter Wire
This 4 conductor twisted-pair cable is for use with the Trimetric
Monitor. Use the 22 gauge wire for up to 55 feet between the batteries
and the monitor and 18 gauge wire for runs of up to 150 feet. The
18 gauge wire is for indoor use and with “Type TC” insulation. Type
TC is suitable for direct burial and is sunlight proof. |
8
Conductor Meter Wire
Use this 18 gauge, 8 conductor twisted pair cable for the E-meter,
which requires twisted pairs. Only 5 conductors are needed for the
standard E-meter. The 3 additional conductors are needed for models
with temperature sensor and LLO options. |
Sensor
Wire
This 3 conductor, 22 gauge direct burial wire can be used between
water level sensors and pump controls in pumping applications where
you must sense water level in a remote tank or in a well. |
Submersible
Pump Wire
2 conductor pump wire is for the Shurflo pump. 3 conductor pump wire
is required for Solarjack and Sunrise pumps. |
|