| These
timers work great for controlling lights, pumps, fans, and small appliances.
They are small enough to fit into electrical load centers. |
12
Volt DC Analog Time Switch
This 12 volt time control switch has a very accurate quartz clock
movement with 200 hour internal power reserve, so it keeps time even
if it is disconnected from the battery or the battery gets low. It
uses 10 mA to operate and can switch to up to 20 amps. Single pole
double throw contacts can turn one thing on while turning another
off. The timer has 3 on-off operations per day. Order extra trippers
for more on/offs per day. Minimum on or off time is 15 minutes. It
can be used to start and stop generators with proper generator control
circuitry. This is a dry-contact unit. Relay requires separate power
to operate. |
| Inventory ID |
| |
Length |
Width |
Height |
Price |
| 12V
Time Switch |
0 |
0 |
0 |
$90.00 |
| 24
Volt Adapter for 12V Time Switch |
0 |
0 |
0 |
$8.00 |
| Extra
tripper, Green (on) |
0 |
0 |
0 |
$1.50 |
| Extra
tripper, Red (off) |
0 |
0 |
0 |
$1.50 |
|
| 52-520-016 |
| 52-520-020 |
| 52-520-021 |
| 52-520-022 |
Voltage & Current
Controlled Relays
| Relays
are electromagnetic switches that can turn on or off a large amount
of current by using a relatively small amount of current. They contain
a coil that produces a magnetic field when a small current is applied.
This magnetic field pulls a metal switch to close the 'Normally Open'
contacts of the relay. When the coil current stops, the spring loaded
switch returns to the 'Normally Closed' position. The coil voltage
rating of a relay is the nominal voltage that must be applied to the
coil to cause the contacts to close. |
Voltage
Controlled Switches
These 12 or 24 volt, user-adjustable, voltage-activated, SPDT relays
have 30 amp contacts and come in active high (coil powered when voltage
rises) or active low (coil powered when voltage drops). Can be connected
either normally open (NO) or normally closed (NC). An active high
relay can be used as a low cost 30A PV regulator, a DC pump controller,
a diversion load control or to operate a large relay for a high powered
charge control. This active low relay can be used as a load disconnect
to prevent over-discharge of batteries. Voltage settings are user-adjustable
and can be read with a voltmeter. These relays consume 17mA when off.
Max current 30A at 12/24VDC, 3A at 48VDC. Measures 3x5.3x1.75 without
enclosure and 5x7x2 with enclosure. |
| Inventory
ID |
|
Voltage
(volts) |
Amperage
(amps) |
Enclosure
|
Price |
| 20-203-103 |
VCS-1
AH |
12-24
|
30. |
NA
|
$78.00 |
| 20-203-104 |
VCS-2
AH |
12-24
|
30. |
indoor
|
$118.00 |
| 20-203-116 |
VCS-1
AL |
12-24
|
30. |
NA
|
$96.00 |
| 20-203-117 |
VCS-2
AL |
12-24
|
30. |
indoor
|
$118.00 |
|
30
Amp DPDT Relays
These double-pole, double-throw relays can be used for up to 30 amps
at 12 or 24 volts DC or 250 volts AC. All contact surfaces are silver
alloy with gold flashing. Contact terminals are #8-32 screws and coil
terminals are #6-32 screws. Relays with 120 VAC or 240 VAC coils can
be used to build simple transfer switches. Relays with DC coils can
be used for remote operation of pumps and fans. By connecting a relay
with a DC coil to a voltage controlled switch, AC loads may be turned
on or off based on battery voltage levels. |
| Inventory
ID |
|
Width |
Height |
Weight
(LBS) |
Price |
| 50-505-071 |
Relay,
DPDT, 30A, 120VAC |
0 |
0 |
18 |
$25.00 |
| 50-505-072 |
Relay,
DPDT, 30A, 12VDC |
0 |
0 |
18 |
$25.00 |
| 50-505-073 |
Relay,
DPDT, 30A, 240VAC |
0 |
0 |
18 |
$25.00 |
| 50-505-074 |
Relay,
DPDT, 30A, 24VDC |
0 |
0 |
18 |
$25.00 |
|
12
Volt 40 Amp SPDT Relay
These single pole, double throw 40 amp enclosed relays are widely
used in the automotive industry. Wires may be attached with 1/4" quick
connect terminals or the relay socket below may be used. Nominal operating
current is 140mA. Relay socket has 2 feet of wire. |
| Inventory
ID |
|
Length |
Width |
Height |
Price |
| 50-505-082 |
Relay
Socket |
0 |
0 |
0 |
$4.00 |
| 50-505-083 |
40A
SPDT Relay |
1 |
2 |
1 |
$8.00 |
|
12
Volt 75 Amp SPST Relay
This enclosed single pole, single throw relay has one set of contacts
that close when power is applied to the coil terminals. It can be
used to turn on 12 volt loads of up to 75 amps. Power terminals are
10-32 screws and coil terminals are Ό quick disconnects. 300mA is
nominal operating current. |
| Inventory ID |
|
Length |
Width |
Height |
Price |
| 50-505-085 |
Relay,
SPST, N.O., 75A, 12VDC |
0 |
0 |
0 |
$18.00 |
|
AC Transfer Switches
& Generator Control
Inverter
Bypass Switch
Wired between your inverter, generator and load center, this unit
allows you to bypass the inverter in the event of an inverter failure.
After the bypass switch is thrown, the inverter can be removed for
repair and the generator is connected directly to the loadcenter.
This is designed for inverters with built-in transfer switches. Maximum
current is 60 amps. Dimensions: 13.5 x 6.25 x 3.5. All components
are UL Listed. |
| Inventory ID |
|
Length |
Width |
Height |
Weight
(LBS) |
Price |
| 53-531-111 |
Inverter
Bypass |
0 |
0 |
0 |
7 |
$100.00 |
|
Automatic
Transfer Switch
Safely connect an inverter and an AC generator to the same house wiring.
Switch can be used with inverters that do not have built-in transfer
switch capability. If the generator is not running, the inverter is
connected to the house wiring. When the generator is started, the
house wiring is automatically disconnected from the inverter and connected
to the generator. A time delay feature allows the generator to warm-up
before the transfer takes place. Use the 120 VAC unit for code installation
of Trace DR or SW inverters in an RV or boat where the neutral and
line terminals must be switched. 2 year warranty. |
| Inventory
ID |
|
Amperage
(amps) |
Voltage
(volts) |
Length
(IN) |
Width
(IN) |
Height
(IN) |
Weight
(LBS) |
Price |
| 53-538-041 |
TS-120/30 |
30. |
120. |
6 |
3 |
6 |
3 |
$80.00 |
| 53-538-053 |
TS-240/50 |
50. |
|
10 |
4 |
12 |
12 |
$180.00 |
|
Gen/Tran
Indoor Hard Wire Transfer Switch
The Gen/Tran transfer switch is designed for hard-wire connection,
instead of cord, when interfacing a portable generator with a load
center. It features six combination 1/2 and 3/4 inch knockouts, making
it well-suited for hard-wire residential and commercial generator
installations. The Gen/Tran transfer switch features a rugged steel
cabinet, resettable circuit breakers, non-defeatable (break-before-make)
double-throw switches, dual wattmeters for measuring and balancing
generator loads, over 70 cubic inches of wiring space, and a convenience
outlet that is live under generator power. 8 Single-pole circuits
maximum or 4 double-pole circuits maximum can be wired in this unit. |
| Inventory ID |
|
Length
(IN) |
Width
(IN) |
Height
(IN) |
Price |
| 53-531-013 |
GenTran
30408 |
7 |
4 |
13 |
$512.90 |
|
Dual Battery Switches
Battery
Selection Switch
This high current switch is designed for battery switching in boats
but can be used in land-based units. It permits selection between
one of two batteries or the connection of both batteries in parallel.
The off position also acts as a battery disconnect. Many people
are using these to choose between two banks of batteries or between
a main battery and a back-up battery. The switch surface mounts with
a slot for wires to enter from the bottom. Wires connect to 5/16
brass bolts. Capacity is 250 amps continuous and 360 amps intermittent.
For use on 6, 12, 24 or 32 volt systems. UL listed for marine use. |
| 45-453-015 |
Battery
Selector Switch |
$32.00 |
|
Dual
Battery Relay
This relay is designed to isolate a second battery in a vehicle. The
contact terminals are connected between the positive terminal of the
starting battery and the positive terminal of the second battery.
The negative terminals of both batteries are connected to the vehicle
chassis. One of the coil terminals is connected to chassis ground
and the other coil terminal is connected to the ignition switch or
fuse box. When the vehicle is running, both batteries are connected
together in parallel and being charged by the alternator. When the
ignition switch is off, the contacts are open, disconnecting the second
battery from the vehicle electrical system. 80 Amp maximum continous
current. 12 volt coil. |
| 50-505-020 |
Dual
Battery Relay |
$20.00 |
|
DC Switches, Plugs & Receptacles
DC
Rated Toggle Switches
These bat handle toggle switches have silver contacts and 11/16 long
chrome plated handles. They mount in a ½ diameter hole in panels
up to 3/8 thick. Mounting hardware is provided. Electrical rating
is 25 amps at 12VDC. Available in single and double throw. Single
pole is a two position on/off switch with screw terminals for wire
connection. Double throw is a three position switch with center off.
Make connections via six 1/4 slip-on male blade terminals. |
| 53-538-034 |
| Single
Pole Single Throw |
$7.00 |
|
DC
Rated Wall Switches
These switches are made for AC or DC wiring and they fit standard
wiring boxes to simplify house wiring. By using a pair of 3-way switches,
you can turn on a light in one place and turn it off in another place.
The switch lever is ivory color. On-Off switch current rating is 10
amps maximum. 3-way switch maximum current is 6 amps. Maximum voltage
is 125VDC. |
| 53-536-048 |
3-Way
Switch Ivory |
$5.00 |
| 53-536-049 |
On-Off
Switch Ivory |
$4.00 |
|
Cigarette
Lighter Plugs & Receptacles
|
In-line
Receptacle
This outlet can handle up to 20 amps. 16 gauge wire leads are 12
long. |
| . 53-536-034 |
| Receptacle,
12V-CL Type, In-Line, 12in |
$5.00 |
|
In-Line
Double Cigarette Lighter Receptacle
Plug two devices into the same outlet with this heavy duty Y connector.
Leads are 6 inches long 16 gauge wire. |
| 53-536-027 |
Receptacle, 12V-CL Type, Y Adapter |
$7.00 |
|
Cigarette
Lighter Plug
This heavy-duty plug is made from high heat thermo-set plastic to
prevent distortion at high temperatures. It comes with an easy to
replace 3 amp glass fuse, but any AGC type fuse up to 15 amps may
be used. Wire connections should be soldered. Screw together assembly
requires no tools. |
| 53-536-025 |
Plug,
12V-CL Type, Fused |
$3.00 |
|
Extension
Cord
Ten foot extension cord with lighter plug at one end and lighter receptacle
at the other. 16 gauge wire. |
| 53-536-035 |
Extension
Cord, 12V-CL Type, 10ft |
$9.00 |
|
Receptacle
With Battery Clips
Ten foot extension cord with lighter receptacle at one end and color
coded battery clips at the other. 16 gauge wire. |
| 53-536-047 |
Receptacle,
12V-CL Type, In-line, 10ft, w/Battery Clips |
$11.00 |
|
Wall
Plate Lighter Receptacle
This receptacle comes with a chrome plated cover that fits a standard
single gang outlet box. This heavy duty outlet is made of brass and
steel so it can handle up to 20 amps. The positive connection is a
10-32 threaded stud with nuts. The negative connection is a short
piece of 18 gauge wire. The negative connection of the outlet is connected
to the steel cover, so it is a good idea to use a steel junction box
with the negative wire connected to the box as well as the negative
lead on the outlet. |
| 53-536-050 |
Receptacle,
12V-CL Type, Wall Plate |
$4.00 |
|
DC
Receptacles and Plugs
In our search for an economical, NEC approved outlet to use for low
voltage systems, we have decided upon something that is readily available,
a 240 volt, 15 amp receptacle. Our choice of this configuration is
based on the assumption that PV-powered remote homes will not normally
have appliances that use 240 volts at 15 amps. If you have a large
power tool it will usually have a 240 volt 20 amp plug on it. The
receptacles are duplex (two outlets) and they fit standard wiring
boxes and standard duplex receptacle covers. |
| 53-536-038 |
Plug
DC/240 V 15A |
$4.50 |
| 53-536-044 |
Receptacle
Brown |
$6.00 |
| 53-536-045 |
Receptacle
Ivory |
$5.50 |
|
|